Can an underground bunker be installed if the plot has a high groundwater level?
Yes, but the solution depends on the exact groundwater level and how much it fluctuates, so geotechnical investigations are carried out before design. Their results determine the installation depth, the base construction and the drainage. Where the water table is high, the design also assesses the risk of an empty body floating up – the body can be fixed to anchor blocks or secured in another way. We propose a precise solution once we have assessed the plot.
Is drainage needed around the bunker?
We determine whether drainage is needed based on the soil properties, the groundwater level and the lie of the land. Drainage is often installed together with the crushed stone or gravel base so that surface water and groundwater do not collect around the body. Drainage also helps keep the backfill soil in a stable condition, on which the load-bearing capacity of the structure depends. If the plot has a stormwater drainage system, the drainage can be connected to it.
Won’t a steel body rust underground?
The body is made from galvanised steel with an additional polymer coating. According to the manufacturer, this coating lasts 100 years or more. The coating system can be chosen to suit how aggressive the soil is, and in the ‘Reinforced’ specification the body is additionally encased in reinforced concrete. It is important that the coating is not damaged during installation – we monitor this while the body is lifted in and backfilled.
How is the bunker ventilated?
Ventilation pipe connections are fitted to the body in the factory, and natural or mechanical ventilation is connected to them. For a blast shelter, we recommend a filtration and ventilation unit with filters against radioactive dust and chemical and biological contaminants, plus blast valves that shut off the outside air supply in the event of an explosion. We select the unit’s capacity according to the room volume and the number of people. Ventilation and lighting can be connected to an independent power source.
Does an underground bunker need a building permit?
It depends on the size, purpose and location of the structure and on the legal status of the plot, so the answer is different in every case. We advise on which construction permit documents are required and prepare the design solutions. If you need an official shelter entered on the municipality’s list of shelters, we recommend reinforced concrete solutions. More about shelter requirements. Before starting work, we always recommend checking the requirements with your municipality.
How deep is the bunker installed?
Standard layouts provide for at least 2 m of soil cover above the body. According to the manufacturer, the body can be installed at a depth of up to 6 m. We determine the exact depth in the design, taking into account the soil, the groundwater level, the required level of protection and the type of entrance – the deeper the bunker, the longer the entrance shaft or stairway.
Can vehicles drive over the bunker, or can a parking area be built above it?
According to the manufacturer, corrugated steel bodies can also be installed in areas with vehicle loads, for example under a car park, often without an additional reinforced concrete load-distribution slab. Whether this is possible on a specific site is decided on the basis of design calculations. If traffic is planned above the bunker, please mention this in your enquiry.
How many people does the bunker hold?
According to the manufacturer, for an extended stay with sleeping places and supplies, up to 6 people are recommended for the PV-6, up to 8 for the PV-10 and up to 9 for the PV-15. This is not capacity under the 1.5 m² of floor area per person standard used to assess the official capacity of shelters: more people can take cover in the shelter for a short time. The exact number of places is calculated in the design. For more people, we suggest a longer or larger-diameter body or a solution with several structures.
Can we fit out the interior ourselves?
Yes. We can deliver and install the body with openings, floor and entry points, and the client can carry out the interior work – electrics, ventilation, furniture – themselves or with their own contractors. In that case, we agree the positions of openings and entry points in advance and provide fit-out recommendations. We can also offer a complete interior fit-out or just individual elements, such as airtight doors and a filtration unit.
How should the bunker be maintained?
At least once a year, it is advisable to check the ventilation and filtration system, the condition and expiry of the filters, the emergency power supply, the lighting and the airtightness of doors and hatches. Stocks of water, food, medicines and hygiene supplies and their expiry dates should be checked regularly. Operating instructions, the evacuation plan and contact details should also be available on paper. When we hand over the bunker, we provide maintenance instructions and train the people responsible.
How does an underground corrugated steel pipe bunker differ from a block bunker?
A corrugated pipe bunker is a single factory-made body that is buried completely underground and takes up almost no surface area. It suits small and medium-sized groups when fast installation is needed. Block bunkers are assembled from reinforced concrete blocks, can be above ground, partially buried or covered with soil, and are easier to scale up for larger numbers of people. We help you compare the options and choose the one best suited to your site.